Service difficulty report · Switch · Urocop EC130B4

Difficulty date
May 25, 2018
Submitted
May 29, 2018
Operation
Air carrier
Aircraft
N151AC
Make and model
Urocop EC130B4
Aircraft serial
3732
Aircraft time
6,794 hours, 17,763 cycles
Engine
Tmeca ARRIEL2B1
Engine time
3,266 hours, 5,896 cycles
Part
Switch
Part number
S1135020019
Condition
Failed
Location
Oil Cooling Fan
Stage of operation
CL
How discovered
O
Nature of condition
M, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SHORTLY AFTER TAKEOFF DURING CLIMB. SCANNED THE AIRCRAFT INSTRUMENTS AND EVERYTHING WAS IN THE NORMAL OPERATING RANGE. NOTICED THE OIL TEMPERATURE HAD CLIMBED AROUND 7-8 DEGREES PAST THE INITIAL SCAN, STILL WITHIN NORMAL OPERATING LIMITATIONS. THE OIL TEMPERATURE WAS INCREASING A DEGREE CELSIUS EVERY 1-2 SECONDS. THE OIL TEMPERATURE WAS STILL WITHIN NORMAL OPERATING RANGE BUT STEADILY INCREASING. HEADED BACK TO DEPARTURE AND NO MORE THAN A QUARTER MILE AWAY FROM THE AIRPORT, THE OIL TEMPERATURE BEGAN TO CLIMB MORE STEADILY. THE OIL TEMPERATURE CLIMBED AND EXCEEDED THE 115 DEGREE CELSIUS LIMITATION. FOLLOWED THE EMERGENCY PROCEDURE AND THE OIL TEMPERATURE DID NOT PLATEAU OR DECREASE. DECLARED AN EMERGENCY. LANDED. ON SHUTDOWN THE LAST OIL TEMPERATURE READING WAS ABOVE 130 DEGREES CELSIUS. THERMOSTATIC SWITCH THAT CONTROLS OIL COOLER FAN WAS FOUND TO NOT RESPOND TO TESTS,