What was found
PILOT RECEIVED A CALL FOR AN INTER HOSPITAL TRANSFER. APPROXIMATLY 6 MINUTES POST DEPARTURE FROM BASE THE FLIGHT CREW STARTED SMELLING SMOKE. A SHORT DISCUSSION TOOK PLACE BETWEEN THE CREW VERIFIYING ALL HAD SMELLED "SMOKE" AT WHICH TIME THE PILOT MADE THE DECISION TO PL @ THE LOCAL HIGHSCHOOL PARKING LOT. DURING THE APPROACH PILOT STATES THE SMELL BECAME STRONGER. ONCE ON THE GROUND THE PILOT INSTRUCTED THE MED CREW TO EVAC AND GET CLEAR OF THE AIRCRAFT. PILOT THEN STATED A PUFF OF SMOKE (VISABLE CLOUD) CLEARLY CAME FROM PILOT SIDE BLOWER MOTOR. PILOT SHUT OFF THE A/C SYSTEM/ BLOWERS & FOLLOWED SHUTDOWN PROCEDURES. PILOT STATED THE REMAINDER OF SHUTDOWN WAS NORMAL.