WHILE IN THE DECELERATION PHASE FOR LANDING, THE "XMSN CHIP" AND MASTER CAUTION LIGHTS ILLUMINATED. ALL OTHER INDICATIONS - TRANSMISSION PRESSURE, TEMP. WERE NORMAL. NO ABNORMAL NOISE OR VIBRATIONS NOTED. LANDING AND SHUTDOWN WERE NORMAL. INSPECTED CHIP DETECTORS, SMALL SILVER FLAKES LESS THAN 1 MM FOUND ON MGB SUMP. WHICH IS NORMAL FOR A TRANS WITH LESS THAN 100FH AS PER THE BELL MANUAL. CURRENT TRANSMISSION TIME SINCE OVERHAUL / INSTALLATION IS 78+23FH. RETAINED FLAKES FOR HISTORICAL USE. DRAINED AND RESERVICED, FILTER CHANGE, AND PERFORMED GROUND RUN.