What was found
ACFT BONDED PANEL ON BELLY WAS PUNCTURED AND DENTED DURING GROUND HANDLING OF HELICOPTER WITH TUG-A-LUG. PERFORMED STRUCTURAL REPAIR ON (LT AFT BELLY) PANEL INSTALLATION PN 222-031-430-101 IAW MFG FIELD REPAIR NR 10RI-013 DATED 04/01/2010 UNDER STATEMENT OF COMPLIANCE SN C0425 DATED 03/30/10. ALSO PERFORMED STRUCTURAL REPAIR ON (RT AFT BELLY)PANEL INSTALLATION PN 222-031-430-103 IAW MFG FIELD REPAIR NR 10RI-014 DATED 03/30/2010 UNDER STATEMENT OF COMPLIANCE SN C0425 DATED 03/30/10. FOR DETAILS, REFER TO CRS QML3253U REPAIR STATION WORK ORDER NR MR018 AND FAA FORM 337 DATED 25 MAY 2010.