What was found
DURING FLIGHT, GENERATOR AMP SPLIT OF 20 -25 AMPS. #1 GENERATOR READS 10 AMPS; #2 GENERATOR READS BETWEEN 35 AND 40 AMPS. REMOVED AND REPLACED CURRENT TRANSFORMER IAW 24-30-00, 4-6. MOC COMPLETED IAW AMM 05-60-00, 6-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING FLIGHT, GENERATOR AMP SPLIT OF 20 -25 AMPS. #1 GENERATOR READS 10 AMPS; #2 GENERATOR READS BETWEEN 35 AND 40 AMPS. REMOVED AND REPLACED CURRENT TRANSFORMER IAW 24-30-00, 4-6. MOC COMPLETED IAW AMM 05-60-00, 6-12.