What was found
YYC - TWO NICKS/CORROSION SPOTS ON RIGHT SIDE FUSELAGE BETWEEN STATION X405.73 AND 424.12, STRINGER 16S AND 17S. REPAIRED IAW DHC-8 SRM 51-20-11, PAGE 3, SECTION B, SRM 51-20-16, PAGE 4, SECTION C, SRM 51-20-36, PAGE 6, SECTION F-J AND SRM 51-20-41.