What was found
C5 CHECK - CORROSION ON FRAME FLANGE AT ST 301.00 BETWEEN STR 31L AND STR 32L. BLENDED AREA OF CORROSION AND FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. HFEC INSPECTED BLEND FOR CRACKS IAW NDTM PART 6, 51-00-01-250-801, NO CRACKS NOTED. ALODINED, PRIMED AND PAINTED REF SRM 51-21-10, 51-25-10 AND 51-25-15, 53-30-43.