Service difficulty report · Relay · Cndair CL6002C10

Difficulty date
August 2, 2003
Submitted
August 7, 2003
Operation
Air carrier
Aircraft
N602QX
Make and model
Cndair CL6002C10
Aircraft serial
10010
Aircraft time
4,028 hours, 3,145 cycles
Part
Relay
Condition
Failed
Location
Thrust Reverser
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PDX- ON FLIGHT 2431 ABORTED TAKEOFF DUE TO RIGHT REVERSE CAUTION MESSAGE APPEARED DURING POWER APPLICATION FOR TAKEOFF. MESSAGE WENT AWAY WHEN THRUST LEVERS RETRACTED TOWARDS IDLE. FOUND FAULT GROUND RELAY AK30 RELAY CLOSED. GROUND RAN AIRCRAFT AND PERFORMED OPERATIONAL TEST OF THRUST REVERSER. NO PARTS REPLACED. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.