Service difficulty report · Actuator · Cndair CL6002C10

Difficulty date
July 2, 2004
Submitted
July 7, 2004
Operation
Air carrier
Aircraft
N611QX
Make and model
Cndair CL6002C10
Aircraft serial
10041
Aircraft time
5,602 hours, 4,060 cycles
Part
Actuator
Part number
AL00102
Part serial
C8376
Condition
Malfunctioned
Location
Zone 300
Part time
5,602 hours, 4,060 cycles
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DEN - FLIGHT 4011- ABORTED TAKEOFF AT 115-120 KTS, MASTER WARNING, RUDDER MISCONFIGURATION. WARNING WENT AWAY WHILE CLEARING RUNWAY. RUDDER AND AILERON INDICATED GREEN. REMOVED AND REPLACED RUDDER TRIM ACTUATOR. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.