What was found
TRACK NR 2 HAS CHAFES ON TOP FLANGE AT X 521.5. BLENDED LIGHT CHAFE, MEASURED AND FOUND WITHIN LIMITS IAW RD 8/4-53-884, STEP 1. AREA 1 INCH LONG BY .25 INCH WIDTH, .004 INCH DEPTH. HFEC INSP IAW 1-84-7A, PART 6, 51-00-02. NO CRACKS NOTED. ALODINED AREA IAW 1400 RD 8/4-53-844, STEP 6.