What was found
LIGHT CHAFING ON TRACK NR 2 AT X 489.0. BLENDED LIGHT CHAFE, MEASURED AND FOUND WITHIN LIMITS IAW RD 8/4-53-844, STEP 1. AREA AT TOP 1.2 INCH LONG, .125 INCH WIDTH, DEPTH .002 INCH. INSIDE CHANNEL 1.2 INCH LONG BY .5 INCH WIDTH, .002 DEPTH. HFEC INSP IAW 1-84-7A, PART 6, 51-00-02. NO CRACKS NOTED. ALODINED AREA IAW Q400 RD 8/4-53-844, STEP 6.