What was found
PDX - TRACK NR 2 HAS LIGHT CHAFING AT 358.2. BLENDED LIGHT CHAFE, MEASURED AND FOUND WITHIN LIMITS IAW RD 8/4-53-884, STEP 1 AREA 1.0 INCH LONG, .5 INCH WIDE AND .002 INCH DEEP. HFEC INSP AS PER 1-84-7A, PART 6, 51-00-02. NO CRACKS NOTED. ALODINED AREA IAW Q400 RD 8/4-53-884, STEP 6.