What was found
PDX - TRACK NR 2 HAS GOUGE IN BETWEEN TOP FLANGES AT X 291.0. BLENDED GOUGE INSIDE CHANNEL, MEASURED AND FOUND WITHIN LIMITS IAW RD 8/4-53-884, STEP 1. AREA 1 INCH LONG, 1.2 INCH WIDE AND .005 INCH DEEP. HFEC INSPECTION AS PER 1-84-7A, PART 6, 51-00-02. NO CRACKS NOTED. ALODINED AREA IAW Q400 RD 8/4-53-884, STEP 6.