What was found
PDX - LITE CORROSION TOP INBOARD FLANGE TRACK NR 2 AT X 568.0. BLENDED LITE CORROSION, MEASURED AND FOUND WITHIN LIMITS IAW RD 8/4-53-884, STEP 1. AREA 2 INCHES LONG, .25 INCH WIDE AND .003 INCH DEEP. HFEC INSPECTION AS PER 1-84-7A, PART 6, 51-00-02. NO CRACKS FOUND. ALODINED AREA IAW Q400 RD 8/4-53-884, STEP 6.