What was found
PDX - SEAT TRACK NR 2 HAS LIGHT CHAFING AT 258.5. BLENDED LIGHT CHAFE, MEASURED AND FOUND WITHIN LIMITS IAW RD 8/4-53-844, STEP 1, AREA 1 INCH LONG, .375 INCH WIDE AND .002 INCH DEEP. HFEC INSPECTION AS PER 1-84-7A, PART 6, 51-00-02. NO CRACKS NOTED. ALODINED AREA IAW Q400 RD 8/4-53-884, STEP 5.