What was found
PDX - TRACK NR 1 HAS LITE CHAFING AT X 220. BLENDED LITE CHAFE, MEASURED AND FOUND WITHIN LIMITS IAW RD 8/4-53-884, STEP 1. AREA AT TOP 5 INCHES LONG, 3.8 INCHES WIDE .003 INCH DEEP, AT INSIDE CHANNEL 1.5 INCH LONG, .5 INCH WIDE, .006 INCH DEEP. HFEC INSPECTION AS PER 1-84-7A, PART 6, 51-00-02. NO CRACKS NOTED. ALODINED AREA IAW Q400 RD 8/4-53-884, STEP 6.