What was found
PDX - LITE FRETTING CORROSION FROM 14 COUNTER SINKS AT FORWARD EDGE OF PANEL USING SCOTCH BRITE ON AFT EDGE OF PANEL. NO MEASUREMENTS TAKEN, FRETTING DAMAGE AND REMOVED CORROSION FROM REMAINING 42 COUNTER SKINS USING SCOTCH BRITE. NO MEASUREMENTS TAKEN. MEASURED AND MAP COUNTER SINKS FOR ENGINEERING EVALUATION. HFEC INSPECTED BLENDS FOR CRACKS IAW D8-400 NDTM PART 1, 51-00-06. NO CRACKS NOTED. REPLACED PANEL WITH NEW FROM STOCK.