Service difficulty report · Bulb · Bombdr DHC8402

Difficulty date
October 14, 2005
Submitted
October 17, 2005
Operation
Air carrier
Aircraft
N415QX
Make and model
Bombdr DHC8402
Aircraft serial
4081
Aircraft time
4,947 hours, 4,770 cycles
Part
Bulb
Condition
Burned Out
Location
Indicator
Stage of operation
TX
How discovered
O
Nature of condition
J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 2 TANK AUX PUMP LIGHT BURNED OUT. SPOILER OUTBD CAUTION LIGHT COMES ON AT 185-190 KTS. MAINTENANCE REMOVED AND REPLACED FCECU AND PERFORMED APPLICABLE OPS TESTS AND FUNCTIONAL TESTS. NO DEFECTS NOTED. REMOVED AND REPLACED NR 2 SPOILER UNLOAD VALVE. PERFORMED APPLICABLE OPS CHECKS. NO DEFECTS NOTED FOR THE NR 2 TANK AUX PUMP LIGHT, MAINTENANCE REPLACED NR 2 TANK AUX PUMP SWITCH LIGHT. NO HELP. REMOVED AND REPLACED ADVISORY CONTROL UNIT IAW Q400 TASK 31-51-06-000-801 AND 31-51-06-400-801. OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.