As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GEG FLIGHT NR 2393: MAIN GEAR DOORS AND GEAR IN TRANSIT CAME ON A FEW SECONDS THEN WENT OUT. DID THIS SEVERAL TIMES. MAINTENANCE PERFORMED INSP OF THE A/C AND ENGINES AS REQUIRED BY PARA C OF THE FERRY FLIGHT PERMIT AND DETERMINED THAT THE A/C IS SAFE FOR FLIGHT FROM GEG TO PDX. IN PDX , MAINTENANCE REPLACED THE LT MLG DOOR CLOSED PROX SENSOR. PERFORMED OPERATIONAL CHECK OF PRIMARY GEAR EXTENSION RETRACTION SYSTEM IAW AMM TASK 32-31-00-710-801. OPS CHECK GOOD. A/C RETURNED TO SERVICE