Service difficulty report · Valve · Bombdr DHC8402

Difficulty date
November 1, 2005
Submitted
November 3, 2005
Operation
Air carrier
Aircraft
N410QX
Make and model
Bombdr DHC8402
Aircraft serial
4053
Aircraft time
9,972 hours, 10,409 cycles
Part
Valve
Part number
4100S00505
Part serial
0222
Condition
Malfunctioned
Location
Deice System
Part time
3,480 hours, 3,278 cycles
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SEA FLIGHT NR 2327: WHILE DESCENDING ON APPROACH AND OAT-2 DEG C, THE DE-ICE PRESSURE CAUTION LIGHT ILLUMINATED. AFTER SELECTING AIRFRAME MODE TO SLOW, THE NR 1 BOOT PAIR LIGHT ON FO'S SIDE WASN'T ILLUMINATED. RAN THE CHECKLIST AND THE DEICE LIGHT DIDN'T GO OUT BUT PRESSURES WERE NORMAL. MAINTENANCE REMOVED AND REPLACED NR 2 DUAL DISTRIBUTION VALVE AND INSTALLED LEADING EDGE 613AR. ALL CHECKS GOOD. NO DEFECTS NOTED. MTX CONTROL WAS NOTIFIED. AIRCRAFT RETURNED TO SERVICE.