Service difficulty report · Pressure Switch · Cndair CL6002C10

Difficulty date
December 21, 2005
Submitted
December 30, 2005
Operation
Air carrier
Aircraft
N608QX
Make and model
Cndair CL6002C10
Aircraft serial
10026
Aircraft time
10,318 hours, 7,629 cycles
Part
Pressure Switch
Condition
Malfunctioned
Location
Hyd System
Stage of operation
TX
How discovered
O
Nature of condition
O
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DEN - ON TAXI FOR FLIGHT 4325 RECEIVED HYD PUMP 1B CAUTION MSG. RETURNED TO THE GATE. FOUND HYD PUMP 1B LOW PRESSURE SWITCH INTERMITTENT WITH PUMP 1B AND NR 1 ENG DRIVEN PUMP 1A OFF HYD PRESSURE INDICATED 2900 PSI WITH HYD PUMP 1B CAUT MSG CYCLED HYD PUMP 1B SWITCH AND DISCONNECTED AND RECONNECTED LOW PRESSURE SWITCH, WITH NR 1B PUMP SELECTED TO ON EICAS SHOWS GREEN WITH NO CAUTION MSG RESCHEDULED IAW MEL 29-34-1. 12/22 REMOVED AND REPLACED NR 1 PUMP PRESSURE SWITCH IAW CRJ 700 AMM 29-34-01-000-801-A01 AND 29-34-01-400-801-A01, OPS CHECK AND LEAK CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.