What was found
YYC - PAX DOOR AFT STRINGER (STAIR SIDE) CRACKED AT HANDRAIL STOWAGE BRACKET. CUT OUT DAMAGED SIDE PANEL AND FABRICATED REPAIR PARTS IAW REO 670-52-11-104 STEPS 1, 3, 4, 5, 6, 7. HFEC INSPECTION C/O ON CUT-OUT REPAIR AREA OF PAX DOOR STAIR WEB AS REQUIRED IAW NDTM PT 1 51-20-006 NO CRACKS FOUND. REMAINING STEPS 2, AND 8 THROUGH 17 COMPLETED IAW REO 670-52-11-104.