What was found
PDX - BURNT RIVET AT STA X30, STRINGER 10L. MAINTENANCE REPAIRED IAW Q400 SRM 51-40-07-320-801. HFEC INSPECTION FOR CRACKS IAW NDTM PART 6, TASK 51-00-01-250-801. NO CRACKS NOTED. C/W RD 8/4-53-721.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PDX - BURNT RIVET AT STA X30, STRINGER 10L. MAINTENANCE REPAIRED IAW Q400 SRM 51-40-07-320-801. HFEC INSPECTION FOR CRACKS IAW NDTM PART 6, TASK 51-00-01-250-801. NO CRACKS NOTED. C/W RD 8/4-53-721.