Service difficulty report · Sensor · Cndair CL6002C10

Difficulty date
August 5, 2006
Submitted
August 7, 2006
Operation
Air carrier
Aircraft
N616QX
Make and model
Cndair CL6002C10
Aircraft serial
10128
Aircraft time
7,650 hours, 5,462 cycles
Part
Sensor
Part number
6007300
Condition
Malfunctioned
Location
Brake Temp
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DEN - AFTER TAKEOFF FOR FLIGHT 4342 (DEN-YYC) RECEIVED A BRAKE OVERHEAT WARNING CLIMBING THROUGH 17,000 FEET. PER THE CHECKLIST, LOWERED THE LANDING GEAR AND MESSAGE WENT OUT. RESET THE BRAKE TEMPERATURE MONITORING SYSTEM. NR 4 BRAKE READ 17 AT HOTTEST POINT. RETURNED TO THE FIELD AND ACCOMPLISHED AN UNEVENTFUL LANDING. MAINTENANCE INSPECTED LANDING GEAR AND WHEELS AND BRAKES. THERE WERE NO SIGNS OF OVERHEATING. AS A PRECAUTION, REPLACED THE NR 4 BRAKE, WHEEL, AND TEMPERATURE SENSOR. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.