As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PDX: FWD CENTER FUSELAGE EXTERIOR - RT SKIN PANEL BETWEEN STA X166 - X176 AND STR 21S AND 20S HAS 1 DENT WITH BLEND OUT .053 DEEP X 1.10 DIA AND A SHARP DENT .032 DEEP X .650 DIA. MAINTENANCE REPAIRED IAW RD 8/4-53-1514, HORIZON EA 6-53-703, RD 8/4-51-043 AND NDTM PART 6, 51-00-01.