What was found
PDX - C3 CHECK, BARE METAL AND IMPACT DAMAGE AT STRINGER 13.5 AND 15 FORWARD OF MAIN CABIN DOOR. BLENDED OUT DAMAGE AND REMOVED .005" MATERIAL, WITHIN LIMITS. TREATED AND PAINTED AREA IAW SRM 51-25-01-001-001-A01. NO PARTS REPLACED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PDX - C3 CHECK, BARE METAL AND IMPACT DAMAGE AT STRINGER 13.5 AND 15 FORWARD OF MAIN CABIN DOOR. BLENDED OUT DAMAGE AND REMOVED .005" MATERIAL, WITHIN LIMITS. TREATED AND PAINTED AREA IAW SRM 51-25-01-001-001-A01. NO PARTS REPLACED.