PDX C3 - 1.4" CRACK IN FLANGE RADIUS OF EMPENNAGE OBLIQUE FRAME AT X935, 11 O'CLOCK POSITION. LEFT SIDE OF CUTOUT FOR V-STAB TUNNEL. REPAIRED IAW Q400 SRM 51-42-05 AND 51-40-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PDX C3 - 1.4" CRACK IN FLANGE RADIUS OF EMPENNAGE OBLIQUE FRAME AT X935, 11 O'CLOCK POSITION. LEFT SIDE OF CUTOUT FOR V-STAB TUNNEL. REPAIRED IAW Q400 SRM 51-42-05 AND 51-40-10.