What was found
GTF FLIGHT: FLAP POWER ON DEPARTURE OUT OF GTF. RAN CHECKLIST AND FLAP POWER STILL ILLUMINATED. LANDED WITH A ZERO FLAP LANDING CHECKLIST. MAINTENANCE C/W WING FLAP SYSTEM ELECTRICAL CHECKS IAW Q400 AMM 27-50-00-760-801. NO FAULTS REPORTED. SYSTEM CALIBRATION VALVES IN CORRECT RANGE. OPERATIONAL TEST GOOD IAW TASK 27-50-00-710-810. FUNCTIONAL TEST C/W IAW TASK 27-51-00-720-801. ALL CHECKS NORMAL. NO FAULTS AT THIS TIME. NO PARTS REPLACED. AIRCRAFT RETURNED TO SERVICE.