What was found
PDX - C4 CHECK, REFERENCE REO 670-53-11-188 SHEET 1 MAP E, BURNED MATERIAL AROUND FASTENER HOLE AT FS 533. .52" UP STRINGER 6L. HFEC COMPLIED WITH, NO CRACKS NOTED. COMPLIED WITH REO 670-53-11-188 PAGE 3 MAP E.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PDX - C4 CHECK, REFERENCE REO 670-53-11-188 SHEET 1 MAP E, BURNED MATERIAL AROUND FASTENER HOLE AT FS 533. .52" UP STRINGER 6L. HFEC COMPLIED WITH, NO CRACKS NOTED. COMPLIED WITH REO 670-53-11-188 PAGE 3 MAP E.