Service difficulty report · Switch · Bombdr DHC8402

Difficulty date
November 15, 2007
Submitted
November 15, 2007
Operation
Air carrier
Aircraft
N423QX
Make and model
Bombdr DHC8402
Aircraft serial
4153
Aircraft time
1,514 hours, 1,442 cycles
Part
Switch
Part number
9604417
Part serial
0215
Condition
Malfunctioned
Location
Hyd Temp
Part time
1,513 hours, 1,440 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SEA FLIGHT NR 2490: NR 1 HYD PUMP FAILED AND CAUTION LIGHT DURING CLIMB-OUT. AIRCRAFT RETURNED TO FIELD. MAINTENANCE FOUND GOOD QUANTITY LEVEL IN NR 1 HYD SYSTEM. FOUND ALL 3 DPI'S AND IN AND ON THE NR 1 HYD SYSTEM. UNABLE TO DUPLICATE PROBLEM. SUSPECT NR 1 HYD RESERVOIR LOW LIMIT SWITCH. REPLACED THE NR 1 HYD RESERVOIR AND THE RESERVOIR 225 DEG F TEMP SWITCHES IAW D8-400 MM 29-11-16-000-801 AND 29-11-16-400-801 AND 29-11-00-710-807. OPS CHECK GOOD. NO LEAKS NOTED. AIRCRAFT RETURNED TO SERVICE.