What was found
PDX - C5 - UPPER SURFACE OF LEFT INBOARD FLAP 5" AFT OF THE LEADING EDGE AT STATION YW139.00 IS CHAFED APPROXIMATELY .30" BY .35". BLENDED OUT CHAFE IAW -8 200 SRM 57-50-16 PG 2 TABLE 1. HFEC INSPECTED BLEND IAW-8 200 NDTM PART 6 51-00-01. NO CRACKS NOTED, UT THICKNESS CHECK IAW -8 200 NDTM PART 1 51-00-04 HIGH .052 LOW .050. FOUND TO BE WITHIN LIMITS IAW -8 200 SRM 57-50-16 PG 2 TABLE 1. ALODINED, PRIMED AND TOP COAT TO THE BLENDED AREA IAW -8 200 SRM 51-20-16, 51-20-36 AND 51-20-51.