What was found
PDX - C4- FROM STA X71.0 TO X94.0 ON THE RIGHT EMERGENCY DOOR LOWER AUX SILL HAS CORROSION AROUND NUT PLATES. REMOVED UPPER THRESHOLD SILL, REMOVED LOWER THRESHOLD BEAM EDGE (PN 85329514-101) BY DRILLING REF Q400 SRM 51-40-07. INSTALLED NEW FROM STOCK LOWER THRESHOLD PIECE BY INSTALLING SOLID RIVETS IAW DASH 8 400 SRM 51-42-05 AND CHERRYMAY RIVETS IAW DASH 8 400 SRM 51-42-15. REINSTALLED UPPER THRESHOLD SILL USING NEW FROM STOCK HARDWARE AS REQUIRED.