What was found
PDX C4 CHECK ZONE 144 AFT FLOOR SUPPORT ANGLE AT STA X600 IS CORRODED AT Y29.5R. REMOVED CORROSION IAW CPM CHAP 4. UT THICKNESS IAW -8 200 PT 1, 51-00-04, HI .083 LOW .077. HFEC INSP. IAW -8 200 NDTM PT 6, 51-00-01 NO CRACKS NOTED. REMOVED .006" MATERIAL FOUND WITHIN LIMITS PER -8 200 SRM 51-20-11 STEP 3. PREP PRIMED, PAINTED IAW 51-20-16, 51-20-36 PARA F,1 AND 51-20-26 PG 8, PARA B(1-6).