What was found
PDX C4 CHECK SUSPECTED CORROSION AT TOP OF X836.452 AND Y9.250 I/B OF BULKHEAD ATTACH POINT UPPER CARGO DECK. CLEANED SMALL AREA OF CORROSION IAW SRM 51-21-00 & SRM 51-26-00. HFEC INSPECTED AREA PER 1-84-7A PT 6, 51-00-02 NO CRACKS NOTED. THICKNESS CHECKED AREA PER 1-84-7A PT 1, 51-00-04. HI .048 LO .045, .003 MAT. REMOVED. PREPPED AREA WITH ETCH AND ALODINE IAW -8 400 SRM 51-21-10 AND APPLIED PRIMER, PAINT IAW SRM -8 400 51-25-10.