What was found
PDX C4 CHECK THERE IS AN AREA OF PITTING 16" TO 29" AFT OF FWD END OF NR 12 SEAT TRACK ON OTBD SIDE. BLEND OUT PITTING, FOUND WITHIN LIMITS IAW RD8/4-53-884. ORIGINAL .081" REMAINING .076" MAT REMOVED .005". HFEC INSPECTED IAW -8 400 PT 6, 51-00-01, NO CRACKS NOTED. ALODINED PRIMED AND PAINTED IAW RD 8/4-53-884 SECT 1 PG 6 APRA 6,7,8.