What was found
PDX C4 CHECK CORROSION ON FUSELAGE FRAME AT STA X234.475 AND RT STR 29. REMOVED CORROSION IAW -8 400 SRM 51-21-00 PARA 1-3 AND 4A(1) & 2 (B). UT THICKNESS CHECKED BLENDED AREA IAW -8 400 NDTM PART 1, 51-00-04, HFEC INSP IAW -8 400 NDTM PART 6, 51-00-01 NO CRACKS NOTED. MAPPED FOR ENGINEERING, WITHIN LIMITS IAW RD8/4-53-2378. ALODINED PRIMED AND PAINTED IAW Q400 SRM 51-21-10, 51-25-65 AND 51-25-15.