What was found
PDX C4 CHECK. LOWER FUSELAGE EXTERNAL SKIN HAS NICK AT STA X1.0 BETWEEN STRINGERS 31R AND 32R. BLENDED OUT DAMAGE WITH SCOTCH BRITE PAD. HFEC INSP IAW Q400 NDTM PT 6, 51-00-01, NO CRACKS NOTED. UT THICKNESS CHECK IAW Q400 NDTM PT 1, 51-00-04 HI .060" LO .057. OUT OF LIMITS IAW RD8/4-53-505. MAPPED FOR ENGINEERING. INSPECTED BLENDED AREA FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-666. PAINTED IAW 400 SRM 51-25-05.