As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PDX - C3 - LT AILERON TOP LEADING EDGE IS CHAFED IN SEVERAL PLACES. BLENDED CHAFE IAW SRM 57-61-01-001-A01. UT THICKNESS CHECKED BLENDED AREAS IAW NDTM 51-20-04 FOUND TO BE OUT OF LIMITS. REMOVED LT AILERON TOP LEADING EDGE IAW SRM 51-42-06 PG 8 STEP 11 AND THE 4 HUCK BOLTS IAW SRM 51-42-21 PG 11 STEP 10. MATCH DRILLED, COUNTERSUNK, AND ALODINED NEW FROM STOCK LEADING EDGE. INSTALLED LEADING EDGE REF SRM 51-42-21, 51-21-11, 51-42-06 AND 51-72-22.