Service difficulty report · Bleed Valve · Dhav DHC8202

Difficulty date
November 20, 2008
Submitted
November 24, 2008
Operation
Air carrier
Aircraft
N345PH
Make and model
Dhav DHC8202
Aircraft serial
476
Aircraft time
25,989 hours, 37,189 cycles
Part
Bleed Valve
Part number
311669101
Part serial
27A218
Condition
Malfunctioned
Location
Nr 2 Engine
Part time
81 hours, 123 cycles
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PDX - NR 2 TORQUE INCREASED EXCESSIVELY. TAKEOFF ABORTED AT LOW SPEED (BELOW 60KTS) AIRCRAFT YAWED ACCORDING TO DIFFERENTIAL POWER. RETURNED TO THE GATE. REPLACED NR 2 ENG IBV IAW MTC 9720024, OPS TEST GOOD. ALSO REPLACED THE NR 1 ENG TSCU IAW MM 72-01-10 PAGE 420 THRU 424 PARA 7 A THRU 7.B.(2)(J). OPS TEST IAW MTC 9720019, OPS TEST GOOD, NO DEFECTS NOTED. RETURNED TO SERVICE.