What was found
STS - LEFT MAIN GEAR UNSAFE INDICATION AND LT MLG DOOR OPEN INDICATION AFTER GEAR SELECTED DOWN ON APPROACH. FERRY TO PDX FOR REPAIRS. INTERROGATED OF PSEU FOUND PRESENT FAULT LGDLK 1 UNREASONABLE FAR. INDUCTANCE VALUE OF LGDLK1 SENSOR WAS AT 7.960 MH BEFORE ADJUSTMENT. RIGGED THE PROXIMITY SENSOR IAW AM TASK 32-61-06-830-801. CHECKED THE INDUCTANCE VALUE OF PROXIMITY SENSOR IAW TASK 32-61-00-280-801, CURRENTLY AT 8.296MH. OP'S TESTED OF THE LANDING GEAR PRIMARY EXTENSION/ RETRACTION SYSTEM IAW TASK 32-31-00-710-801. OP'S CHECKED GOOD. RETURNED TO SERVICE. NO PARTS.