What was found
PDX - C3 - LIGHT CORROSION ON STRUCTURE AT THE MATING SURFACE OF CARGO BAY PANEL 144JZ. REMOVED CORROSION REF SRM 51-21-00 PAGE 2, PARA A(1), (2)(A). UT THICKNESS IAW NDTM PART 1, 51-00-04 HIGH .050 LOW .046. HFEC AT BLENDED AREA FOR CRACK IAW NDTM PART 6 51-00-01, NO CRACKS NOTED. REMOVED .004 INCH AND FOUND TO BE WITHIN LIMITS REF SRM 51-14-00 PG 204 PARA 7 (A) THRU 3. APPLIED ALODINE TO MATING SURFACE OF CARGO BAY PANEL 144JZ REF SRM 51-21-10-02-01 PARA 5D. PRIMED AREA REF SRM 51-25-10-02-01 PARA 5D.