What was found
PDX - C2 - LIGHTENING BURN AT RIVET FS449 AND STR 1L. STRIPPED PAINT AND REMOVED RIVET PER CRJ 700 SRM 51-42-06. MAPPED AREA FOR ENGINEERING. ENLARGED COUNTERSINK TO .306 INCH TO TRY TO REMOVE DAMAGE PER ENGINEERING REQUEST, DAMAGE REMAINS IN SKIN. RE MAPPED AREA FOR ENGINEERING. ENLARGED COUNTERSINK TO .058 INCH DEEP TO REMOVE DAMAGE PER ENGINEERING REQUEST. NO DAMAGE REMAINS IN SKIN. INSTALLED AN MS20426AD6 AND SHAVED HEAD FLUSH. HFEC INSPECTED DAMAGED AREAS FOR CRACKS IAW REO 670-53-00-179, SHEET 2 REPAIR STEP 3, NO CRACKS NOTED. ALODINED, PRIMED, AND PAINTED AFFECTED AREA IAW REO 670-53-00-179 SHEET 2 REPAIR NOTE 6. ALL ABOVE WORK ACCOMPLISHED AND FOUND TO BE WITHIN LIMITS AS PER REO 670-53-00-179.