What was found
PDX - C2 - 2 LIGHTENING ABOVE STR 1R BETWEEN FS 321 AND FS 323.5. STRIPPED PAINT AND REMOVED RIVET PER CRJ 700 SRM 51-42-06. MAPPED FOR ENGINEERING. ENLARGED COUNTERSINK TO FIT A -5 426 RIVET TO REMOVE DAMAGE PER ENGINEERING REQUEST AND FOUND NO DAMAGE REMAINING. BLENDED OUT MINOR PITTING AND BURN MARK AT FS 321.1 AND FOUND TO BE WITHIN LIMITS IAW REO 670-53-00-179 WITH .010 INCH OF MATERIAL REMOVED. HFEC INSPECTED DAMAGED AREA FOR CRACKS IAW REO 670-53-00-179, SHEET 2, REPAIR STEP 3. NO CRACKS NOTED. INSTALLED RIVET, ALODINED, PRIMED AND PAINTED IAW REO 670-53-00-179 SHEET 2, REPAIR NOTES 4, 5, AND 6. ALL ABOVE WORK ACCOMPLISHED AND FOUND TO BE WITHIN LIMITS AS PER REO670-53-00-179.