What was found
PDX - C5 - SUSPECT CRACK AT V STAB CONNECT ANGLE 4 INCHES IN FRONT OF RUDDER BASE LEFT SIDE. HFEC AT SUSPECTED AREA FOR CRACK IAW NDTM PART 1, 51-20-06. CRACK CONFIRMED. MAPPED AREA FOR ENGINEERING. CUT OUT DAMAGED AREA IAW REO 670-53-84-093. HFEC INSP CUT OUT AREA FOR CRACKS IAW CRJ 700 NDTM PART 6, 53-00-000-250-A01, NO CRACKS NOTED. FABRICATED ANGLE FILLERS AND DOUBLER IAW T/C REO 670-53-84-093. INSTALLED COUNTERSINK FILLERS, ANGLE FILLER AND DOUBLER IAW T/C REO 670-53-84-093. SEALED, PRIMED AND PAINTED IAW REO670-53-84-093.