What was found
BOTTOM OF FUSELAGE IS GOUGED AT APPROX FS 985 BL0 (BETWEEN STR26L AND 26R). BLENDED AREA OF GOUGE TO REMOVE DAMAGE IAW SRM 53-61-01-101. HFEC IAW NDTM PART 1 51-20-006, NO CRACKS NOTED. UT THICKNESS IAW NDTM PART 1 51-20-004 LO .054. MAPPED FOR ENGINEERING. REMOVED EXISTING FASTENERS FROM AFFECTED AREA AND CUT OUT DAMAGE REF REO 670-53-61-474 NOTE 1. HFEC INSPECTED CUT OUT AREA FOR CRACKS IAW REO670-53-61-474/3 NOTE 2. NO CRACKS NOTED. CONTINUED REPAIR IAW REO670-53-61-474/3 NOTES 3. FABRICATED REPAIR DOUBLER, DRILLED UP DOUBLER AND FILLER, INSTALLED COUNTERSINK FILLER IN TWO EXISTING AIRFRAME HOLES DEBURRED EXTERIOR SKIN AND REPAIR PARTS, ALODINED AND PRIMED REPAIR PARTS AND SKIN CUTOUT REF REO670-53-61-474 NOTES 4,6TO 8 AND 10, NOTE 5 IS NA (NOT REQUIRED). INSTALLED HIGH LIGHTS INTO DOUBLER IAW REO670-53-61-474 NOTES 9, 12 ,AND 13-16. NOTE 14 IS N/A AS EXISTING BLENDOUT IS REPAIRED IAW REO 670-53-61-474. INSPECTED AREA OF C-CHANNEL TO BE TRIMMED PER MODSUM IS670538200021 AND FOUND MODSUM TO HAVE BEEN PCW. COMPLIED WITH FINISH CODE IAW REO 670-53-61-474 STEP 11 SHEET 4 AND FINISH CODES ON SHEET 3 PARTS LISTING.