What was found
PDX - C5 - LIGHTNING STRIKE ON FUSELAGE SKIN REQUIRES PERMANENT REPAIR AT FS 485.00 AND STRINGER 25L PER REO670-53-135/3. REMOVED FASTENERS FROM REPAIR AREA, CUT OUT DAMAGE AND DEBURRED IAW TC REO670-53-31-135/3. HFEC INSPECTED AT CUT OUT AND UNDERLYING STRUCTURE FOR CRACK IAW NDTM PART 1, 51-20-006. NO CRACKS NOTED. FABRICATED DOUBLER AND PACKER, DRILLED , COUNTERSUNK AND DEBURRED. ALODINED AND PRIMED ALL BARE METAL. INSTALLED COUNTERSINK FILLERS IAW TC REO 670-53-31-135/3. INSTALLED DOUBLER IAW TC REO670-53-31-135/3.