Service difficulty report · Panel · Cndair CL6002C10

Difficulty date
May 10, 2009
Submitted
May 12, 2009
Operation
Air carrier
Aircraft
N600QX
Make and model
Cndair CL6002C10
Aircraft serial
10005
Aircraft time
19,992 hours
Part
Panel
Condition
Cracked
Location
Cargo Door
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFT SIDE PANEL ON THE MCD IS CRACKED NEAR THE POWER ASSIST MOTOR ATTACH BRACKET & BEAM FOR GAS SPRING REF 52-11-04-001-A01. MAPPED AREA FOR ENGINEERING. REMOVED AFT COUNTER BALANCE SYS REF 52-11-17-000-802. REMOVED THE GAS SPRING BEAM REF SRM 51-42-06 FOR RIVET REMOVAL. FOUND ADDITIONAL CRACKS IN SIDE WALL SKIN 2 INCH TO LT OF ORIGINAL CRACK. MAPPED FOR ENGINEERING. CUT OUT DAMAGED AREA PER REO 670-52-11-416. HFEC INSP CUT OUT FOR CRACKS IAW NDTM PART 6, 53-00-000-250-A01. NO CRACKS NOTED & REO 670-52-11-416. FABRICATED DOUBLER FILLERS & SHIMS IAW REO 670-52-11-416. INSTALLED DOUBLER REF SRM 51-42-06, REO 670-52-11-416. RE-INSTALLED AFT PAX DOOR COUNTER BALANCE SYSTEM IAW AMM 52-11-17-400-802-A01.