What was found
PDX - C5 - LT INBOARD SEAT TRACK FRAME STATION X624 THRU X644 HAS POSSIBLE CORROSION. BLENDED AREA OF CORROSION TO REMOVE DAMAGE AND FOUND BLEND TO BE WITHIN LIMITS IAW RD 8/4-53-884 WITH .013 OF MATERIAL REMOVED FROM INSIDE OF TRACK. HFEC INSPECTED BLENDED AREAS INSIDE OF TRACK FOR CRACKS IAW NDTM PART 6, 51-00-01. NO CRACKS NOTED. CONTINUED BLENDING CORROSION ON LT INBD SEAT TRACK FS X624 TO FS X644 ON INBD FLANGE. REMOVED .011 MATERIAL WITHIN LIMITS REF RD 8/4-53-884 PG 6 GENERAL NOTES 1. PERFORMED HFEC INSPECTION ON BLEND IAW 1-84-7A, PT-6, 51-00-02, NO CRACKS NOTED. APPLIED ALODINE PRIMER AND ALUM ENAMEL PAINT AT LT INBD SEAT TRACK FS 624 TO FS 644 ON INBOARD FLANGE REF RD 8/4-53-884 PG 6 GENERAL NOTES PG 6 4-8.