What was found
PDX - C5 - LIGHT SURFACE CORROSION ON RT FUSELAGE AT FS X289.0 STRINGER 13S. REMOVED LIGHT SURFACE CORROSION ON RT FUSELAGE AT FS X289.0 STR 13S. ALODINED IAW SRM 51-21-10-02-01, 51-21-00-00-02. PERFORMED HFEC OF BLENDED AREA FOR CRACKS IAW NDTM PART 6, 51-00-01, NO CRACKS NOTED. UT THICKNESS CHECK IAW NDTM PART 6, 51-00-04 HIGH .062 LOW .053. INSPECTED AREA AND FOUND BLEND TO BE OUT OF LIMITS IAW RD 8/4-53-505 WITH .009 OF MATERIAL REMOVED. MAPPED FOR ENGINEERING. INSPECTED AREA OF BLEND AND FOUND IT TO BE WITHIN LIMITS IAW 8/4-53-2721. REPRIMED BARE AREA IAW RD 8/4-53-2721.