What was found
PDX - C1 - LT INBD SEAT RAIL AT APPROX STA 714 TO 737 HAVE LIGHT SURFACE CORROSION ON FLAT SURFACE INSIDE OF LUGS. REMOVED CORROSION FROM AFFECTED AREA IAW RD 8/4-53-884 NOTES 1,3 AND 5. MAX DEPTH OF BLEND IN SEAT TRACK CHANNEL IS .023 INCH BLEND IS WITHIN LIMITS AS PER RD 8/4-53-884. PERFORMED HFEC INSP BLENDED AREA FOR CRACKS IAW Q400 NDTM PART 6, 51-00-01-250-801, NO CRACKS NOTED. ALODINED PRIMED AND PAINTED BLENDED AREA IAW RD 8/4-53-884 GEN NOTES 4, 6.